Armoured and Un-armoured Power Cable

PVC Insulated, Un-Armoured, PVC Sheathed Power Cables > /
PVC Insulated, Steel Wire Armoured, PVC Sheathed Power Cables > /
PVC Insulated, Steel Tape Armoured, PVC Sheathed Power Cables > /
XLPE Insulated, Un-Armoured, PVC Sheathed Power Cables > /
XLPE Insulated, Steel Wire Armoured, PVC Sheathed Power Cables > /
XLPE Insulated, Steel Tape Armoured, PVC Sheathed Power Cables >


• Rated Voltage: 600/1000V
• Construction: Shaped stranded copper conductors / Flame retardant insulated with PVC compound / PVC bedded / Flame retardant PVC sheathed overall
• Range: 1.5mm² - 500mm², 2 - 4 x 1.5mm² - 400m²
• Application: For fixed installation of the transmission and distribution systems, tunnels and pipelines and other occasions / For situation not suppose to bear external mechanical force


• Rated Voltage: 600/1000V
• Construction: Shaped and circular stranded copper conductors / Flame retardant insulated with PVC compound / PVC bedded / Flame retardant PVC sheathed overall
• Range: 3 x 1.5mm² - 35mm² + 1 x 1.0mm² - 16mm² (Circular Conductor), 3 x 25mm² - 400m² + 1 x 10mm² – 185mm² (Sector and Circular Conductor)
• Application: For fixed installation of the transmission and distribution systems, tunnels and pipelines and other occasions / For situation not suppose to bear external mechanical force


• Rated Voltage: 600/1000V
• Construction: Shaped stranded copper conductors / Flame retardant insulated with PVC compound / PVC bedded / Flame retardant PVC sheathed overall
• Range: 3 x 1.5mm² - 35mm² + 2 x 1.0mm² - 16mm² (Circular Conductor), 3 x 50mm² - 300m² + 2 x 16mm² – 150mm² (Sector and Circular Conductor)
• Application: For fixed installation of the transmission and distribution systems, tunnels and pipelines and other occasions / For situation not suppose to bear external mechanical force


• Rated Voltage: 600/1000V
• Construction: Shaped and circular stranded copper conductors / Flame retardant insulated with PVC compound / PVC bedded / Flame retardant PVC sheathed overall
• Range: 4 x 1.5mm² - 35mm² + 1 x 1.0mm² - 16mm² (Circular Conductor), 4 x 50mm² - 300m² + 1 x 16mm² - 150mm² (Sector and Circular Conductor)
• Application: For fixed installation of the transmission and distribution systems, tunnels and pipelines and other occasions / For situation not suppose to bear external mechanical force


• Rated Voltage: 600/1000V
• Construction: Bare stranded or solid copper conductors /Flame retardant colour-coded PVC insulation / Flame retardant PVC jacket
• Range: 5 - 48 x 1.5mm² - 4.0mm²
• Application: Place indoor, tunnel, conduit, and not suppose to bear external mechanical force / For power control circuits, power stations, underground tunnels, instrumentation, alarm systems

General Usage PVC Insulated Flexible Wire > / General Usage PVC Flexible Wire > / Rubber Insulated Flexible cable > / Armoured Power Cable > / LSOH Wire & Cable > / Fire resistant Cable >