Fire Performance Cable


• Rated voltage: 450/750V, 600/1000V
• Construction: Bare stranded or solid copper conductor / Mineral ceramic (Mica/Glass) fire resistant tape / LSOH insulation
• Range: 0.5mm² – 400mm²
• Application: For fixed wiring / Essential safety circuits where the cable is protected by trunk or conduit


• Rated Voltage: 300/500V, 450/750V
• Construction: Bare stranded or solid copper conductor / LSZH insulation
• Range: 0.5mm² - 400mm²
• Application: For fixed wiring / Can be placed into trunk and conduit / For situations in which low emission of smoke and acid gases is required in the case of burning


• Rated Voltage: 300/500V, 450/750V
• Construction: Stranded copper conductor / LSZH insulation
• Range: 0.5mm² - 240mm²
• Application: For light or medium size home appliances, instrument & meters, and power-driven lighting / For situations in which low emission of smoke and acid gases is required in the case of burning


• Rated Voltage: 300/300V, 300/500V
• Construction: Stranded copper conductor / Flame retardant color-coded LSZH insulation / Flame retardant LSZH jacket
• Range: 2 - 5 x 0.5mm² - 2.5mm²
• Application: For light or medium size home appliances, instrument & meters, and power-driven lighting / Used in energy networks in refineries, high constructions, business centers where there is risk of fire


• Rated Voltage: 450/750V
• Construction: Fine copper conductor / Flame retardant color-coded LSZH insulation / Flame retardant LSZH jacket
• Range: 1 - 5 x 1.5mm² - 35mm²
• Application: Used in energy networks in refineries, high constructions, business centers where there is risk of fire / Used for equipment in industry works such as boilers, heating plates, hand lamps, electric tools (drills, circular saws) and transportable motors or machines at site / Used in electrical equipment under medium stress in dry and damp interiors


• Rated Voltage: 600/1000V
• Model: FR/XLPE/LSZH (FR10)
• Construction: Stranded copper conductors / Mica/Glass fire resistant tape / Insulated with cross-link polyethylene compound / LSZH bedded / LSZH sheathed overall
• Range: 1.5mm² - 1000mm², 2 - 4 x 1.5mm² - 400m²
• Application: For nuclear power plants, underground railways, tunnels, airports, docks, radio tower and other high fire resistant requirements situation


• Rated Voltage: 600/1000V
• Model: FR/XLPE/LSZH (FR10)
• Construction: Stranded copper conductors / Mica/Glass fire resistant tape / Insulated with cross-link polyethylene compound / LSZH bedded / LSZH sheathed overall
• Range: 5 – 48 x 1.5mm² - 4.0mm²
• Application: For nuclear power plants, underground railways, tunnels, airports, docks, radio tower and other high fire resistant requirements situation / For situations in which low emission of smoke and acid gases is required in the case of burning


• Rated Voltage: 600/1000V
• Model: FR/XLPE/SWA/LSZH (FR30)
• Construction: Stranded copper conductors / Mica/Glass fire resistant tape / Insulated with cross-link polyethylene compound / LSZH bedded / Galvanized steel wire / LSZH sheathed overall
• Range: 1.5mm² - 1000mm², 2 - 4 x 1.5mm² - 400m²
• Application: For areas where the integrity of the electrical circuit is critical in maintaining power supply / Protection against mechanical aggressions and rodents


• Rated Voltage: 600/1000V
• Model: FR/XLPE/SWA/LSZH (FR30)
• Construction: Stranded copper conductors / Mica/Glass fire resistant tape / Insulated with cross-link polyethylene compound / LSZH bedded / Galvanized steel wire / LSZH sheathed overall
• Range: 5 – 48 x 1.5mm² - 4.0mm²
• Application: For areas where the integrity of the electrical circuit is critical in maintaining power supply / Protection against mechanical aggressions and rodents


• Rated Voltage: 600/1000V
• Model: XLPE/LSZH (LH10)
• Construction: Stranded copper conductors / Insulated with cross-link polyethylene compound / LSZH bedded / LSZH sheathed overall
• Range: 1.5mm² - 1000mm², 2 - 4 x 1.5mm² - 400m²
• Application: For power stations, underground railways, tunnels, trenches, airports, docks, high-rise buildings and other occasions / For situations in which low emission of smoke and acid gases is required in the case of burning


• Rated Voltage: 600/1000V
• Model: XLPE/LSZH (LH10)
• Construction: Stranded copper conductors / Insulated with cross-link polyethylene compound / LSZH bedded / LSZH sheathed overall
• Range: 5 – 48 x 1.5mm² - 4.0mm²
• Application: For power stations, underground railways, tunnels, trenches, airports, docks, high-rise buildings and other / For situations in which low emission of smoke and acid gases is required in the case of burning occasions


• Rated Voltage: 600/1000V
• Model: XLPE/SWA/LSZH (LH30)
• Construction: Stranded copper conductors / Insulated with cross-link polyethylene compound / LSZH bedded / Galvanized steel wire armoured / LSZH sheathed overall
• Range: 10mm² - 1000mm², 2 - 4 x 1.5mm² - 400m²
• Application: For nuclear power plants, underground railways, tunnels, airports, docks, radio tower and other high fire retardant requirements situation / Protection against mechanical aggressions and rodents


• Rated Voltage: 600/1000V
• Model: XLPE/SWA/LSZH (LH30)
• Construction: Stranded copper conductors / Insulated with cross-link polyethylene compound / LSZH bedded / Galvanized steel wire armoured / LSZH sheathed overall
• Range: 5 – 48 x 1.5mm² - 4.0mm²
• Application: For power stations, underground railways, tunnels, trenches, airports, docks, high-rise buildings and other occasions / For situations in which low emission of smoke and acid gases is required in the case of burning / Protection against mechanical aggressions and rodents


• Rated Voltage: 300/500V
• Model: FR FireAlarm
• Construction: Solid or stranded bare copper conductors / Mica/Glass fire resistant tape / Insulated with cross-link polyethylene compound / Electrostatic screen of plastic coated aluminium foil with tinned drain-wire 0.5mm2 (7x0.3mm) / LSZH sheathed overall
• Range: 2 – 4 x 1.0mm² - 4.0mm²
• Application: For nuclear power plants, underground railways, tunnels, airports, docks, radio tower and other high fire resistant requirements situation / For situations in which low emission of smoke and acid gases is required in the case of burning

General Usage PVC Insulated Flexible Wire > / General Usage PVC Flexible Wire > / Rubber Insulated Flexible cable > / Armoured Power Cable > / LSOH Wire & Cable > / Fire resistant Cable >